1. Original Design: Lightly Loaded Roller Rink

Building records show the top floor was designed as a lightly loaded roller rink, but the approved plan was later changed to a restaurant floor.

0:00 - 0:45
according to building records the new top floor is intended to be lightly loaded this will reduce the additional load on the building beneath in the initial drawings for the fifth floor it shows a roller rink at that locationa roller rink of course is a mostly open space with only the weight of people roller skating around on it but this lightly loaded design is never built after approval had been granted the use changed and it wasturned into a restaurant floor that's nothing like a roller rink a restaurant of course has tables and chairs the people who are eating and sometimes some pretty heavy equipment in order to provide those services this fundamentally changes things

2. Increased Load Without Recalculation

Converting the floor to a restaurant raised the load from 1 to 1.5 tons per square meter, but the structural calculations were never redone.

the structural load calculations for the roller rink suggested that it would need to support about 1 ton for every square meter when it's changed to a restaurant floor the load goes up to about 1 and 1/2 tons persquare meter but they don't recalculate and that's a very significant increase in load and photographic evidence from the site reveals clues that this additional floor was inherently weaker than the floors below a big Divergence from the original design

3. Weakened Columns and Reduced Rebar

The columns deviated from the original design, with reduced diameter and half the reinforcing steel, making the structure significantly weaker.

was that the columns were supposed to be 80 cm in diameter with 16 rebars but the fourth and fifth floor columns weren't like that when the building was finished rebar is the steel reinforcement buried inside the concrete columnseight of the 16 columns had been reduced from 80 cm diameter down to 60 cm diameter and the amount of reinforcing Steel in the columns have been cut in half that decision has consequences reducing the column sizes isgoing to make the structure weaker